Good Read Beep Length

Specifies the duration of a good read beep.

To set the good read beep length:

1. Scan the SWITCH bar code.

2. Scan the bar code,

SET GOOD READ BEEP LENGTH

. You’ll need

to cover any unused bar codes on this and the facing page to ensure
that the scanner reads only the bar code you intend to scan.

3. Scan the appropriate digits from the keypad in Appendix C that rep-

resent the desired good read beep length setting. The selectable
range is 1-255, which is the timeout in 10-millisecond increments.
Pad all single and double digit numbers with leading zeroes to yield
a three-digit entry (001-255).
Examples:

001 = 10ms

005 = 50ms

040 = 400ms

250 = 2,500ms (2.5 seconds)

4. The scanner will automatically exit Programming Mode when the

appropriate amount of digits have been scanned