4-4

Magellan

®

9500

Error

Code

Probable Cause

Corrective Action

0

Blinking

Configuration

No POS interface has been selected (Null interface). See the topic,
Interface Type, in Chapter 6 to select the required interface using pro-
gramming bar codes.

1

Configuration Error

See

Chapter 6

,

Programming, for details about configuring the

scanner using programming bar codes.

2

Interface Board

Unplug unit and call technical support personnel.

3

Motor

Unplug unit and call technical support personnel.

4

Horizontal Laser

a

Call technical support personnel.

5

Vertical Laser

a

Call technical support personnel.

6

Digital Board

Unplug unit and call technical support personnel.

7

Scale

See the topic

Scale Error Reporting in this chapter for problem identi-

fication and corrective actions.

8

Remote Display

Connect the Remote Display. If necessary, replace display or cable.
Alternatively, you can disable the Remote Display using the program-
ming procedures described in

Chapter 6

.

9

EAS Error

No EAS communication. Check EAS cable connections. Call technical
support personnel.

A

Button Module

Call technical support personnel.

C

Scale Calibration

Proceed to scale calibration procedure.

Decimal
Point

3.3 V Present

If not lit, call technical support personnel

a. If only one laser is non-functional, the scanner may continue to work (this is a configurable feature);

however, the 7-segment display will show the error code indicating the failed laser. If both lasers have
failed, the 7-segment display will display either a 4 or a 5, and the scanner will cease to function until
serviced. No alternate blinking of lamps will occur if only one laser has failed.