Codabar Enable

Product Reference Guide

6-243

Codabar Maximum Label Length

This feature specifies the maximum allowable length of a Codabar label.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan the bar code,

SET CODABAR MAXIMUM LABEL LENGTH

below. You’ll need to cover any unused bar codes on this and the fac-
ing page to ensure that the scanner reads only the bar code you
intend to scan.

3. Scan the appropriate digits from the keypad in Appendix C that rep-

resent the desired maximum label length. The selectable range for
this option is 03 to 50. Pad all single digit numbers with a leading
zero to yield a two-digit entry (03-50).

4. Complete the programming sequence by scanning the SWITCH

bar code.

SET CODABAR MAXIMUM LABEL LENGTH

NOTE

Length in this case includes start, stop or check and data characters, but
does not include full ASCII shift characters. This feature applies when

Coda-

bar Length Control is set to variable-length decoding.

Maximum label length should be greater than or equal to minimum label
length.