Standard 2 of 5 maximum label length, Standard 2 of 5 maximum label length -275 – Datalogic Scanning 9500 User Manual

Page 391

Advertising
background image

Standard 2 of 5 Enable

Product Reference Guide

6-275

Standard 2 of 5 Maximum Label Length

This feature specifies the maximum allowable length of a Standard 2 of 5
label.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan the bar code,

SET STANDARD 2 OF 5 MAXIMUM LABEL

LENGTH

below. You’ll need to cover any unused bar codes on this

and the facing page to ensure that the scanner reads only the bar
code you intend to scan.

3. Scan the appropriate digits from the keypad in

Appendix C

that

represent the desired maximum label length. The selectable range
for this option is 01 to 50, even numbers only. Pad all single digit
numbers with a leading zero to yield a two-digit entry (01-50).

4. Complete the programming sequence by scanning the SWITCH

bar code.

SET STANDARD 2 OF 5 MAXIMUM LABEL LENGTH

NOTE

Length in this case includes check and data characters, but does
not include start or stop characters. This feature applies when
Standard 2 of 5 Length Control is set to variable-length decoding.

Maximum label length should be greater than or equal to minimum
label length.