Datalogic Scanning 9500 User Manual

Page 94

Advertising
background image

4-8

Magellan

®

9500

Figure 4-3. Problem Isolation: Selftest

Call Tech Support

Call Tech Support

Error code 4. indicates a failed
horizontal VLDM (laser) assembly,
while 5. indicates a failed vertical
VLDM. If configured to do so1, the
scanner will remain operational
with only one of these lasers until
the unit can be serviced. If both
lasers have failed, the unit will no
longer function.

1

Refer to the feature Laser Failure

Mode in Section 6.

NO

YES

Does the

7-segment

display show

2. or 3.

?

NO

YES

Does the

7-segment

display show

4. or 5.

?

NO

NO

YES

Does the

7-segment

display show

7 or A.

?

NO

YES

Does the

7-segment

display show

8.

?

Does the

7-segment

display show

C.

?

Does the

7-segment

display show

9.

?

Go to Remote Display
flowchart

Go to EAS System
flowchart

Go to Scale flowchart

Unit passes Selftest

YES

YES

NO

Does the

7-segment

display show

0

?

YES

YES

NO

NO

Does the

7-segment

display show

1.

?

Does the

7-segment

display show

1.

?

SELFTEST

START

No interface selected
(Null Interface).
Select an interface.

Scan the Factory
Defaults bar code in
Section 6 to enable the
default configuration
file. Restart the unit.

For this error, the Remote Display
may also show -0- or an error (E__#).

Advertising