9500

Swapping Position: EAS Single-Antenna ONLY

The EAS Antenna must be located in the position needed for your instal-
lation. Reference

Figure 2-18

and. Locate it as described below:

1. Remove the platter (see

Figure 2-22

).

2. If the unit is a model containing a scale, and the scale assembly is

determined to be in the position the EAS Single-Antenna should be
with regard to product flow, proceed to the next step. Otherwise,
skip to step

7.

3. Remove the screws that fasten the Load Cell/Spider Assembly to the

scanner (see

Figure 2-18

) and carefully lift the entire assembly from

the scanner cavity. Retain the screws for re-installation.

Figure 2-18. Locating the EAS Single-Antenna (Right-to-Left)

EAS Antenna

Load Cell/Spider

Assembly

Load Cell Harness

Product Flow

Product Flow