F-7

Code 39

Check character must be included in label data.

Label length including start, stop and check characters and exclud-
ing prefix character must meet requirements imposed by the main
scanner's fixed or variable label length control for this symbology
type.

Start and stop characters "*" must be included in label.

Prefix must be an ASCII character '*'.

Example : '**Code 39.TEST*'.

Code 39-Pharmacode

Check character must be included in label data.

Label length including start, stop and check characters and exclud-
ing prefix character must meet requirements imposed by the main
scanner's fixed or variable label length control for this symbology
type.

Start and stop characters "*" must be included in label.

Prefix must be an ASCII character 'p'.

Example: 'p*123456789*'.

I 2 of 5

Check character must be included in label data.

Label length including check characters and excluding prefix charac-
ter must meet requirements imposed by the main scanner's fixed or
variable label length control for this symbology type.

Prefix must be an ASCII character 'i'.

Example: 'i0123456789'.