Installation Overview

Product Reference Guide

2-23

Scale:

If the Yellow (middle, scale) LED is not lit, press the Scale Zero

Push Button momentarily. If the scale is operating correctly, the yel-
low LED will illuminate and remain on steady, and the display will
show a reading of 0.00 lb (0.000 kg for metric). If the display is
blank or a

is displayed, it may be necessary to calibrate

the scale before continuing. Refer to

Chapter 5

,

Calibration

, for cal-

ibration procedures.

Remote Scale Display:

Check to verify that 0.00 lb (0.000 kg for met-

ric) is displayed, then place an item on the weighing platter. Verify
that the display shows a weight and that the yellow LED goes out.
Remove the item and observe that Remote Scale Display shows 0.00
lb (0.000 kg for metric) and that the yellow LED is On.

6. Unplug the AC power cord from the outlet and disconnect the

power cord and Remote Scale Display cable from the scanner’s con-
nector panel.

After you have verified that the scanner, EAS system and scale (if present)
are completely functional, continue with the following procedures to
complete the installation.