Datalogic handheld data format requirements – Datalogic Scanning 9500 User Manual

Page 444

Advertising
background image

F-2

Magellan

®

9500

Datalogic Handheld Data Format Requirements

The following sections describe label transmission formats that are typi-
cally observed in factory configurations of Datalogic handheld scanners.

RSS-14

Prefix must be ASCII characters ‘R4’

Check character must be included in label

Application identifier “01” must follow the prefix and preceed the
base label

Label length excluding prefix characters must be 16 characters.

Example: ‘R40101044123456789’

RSS Expanded

Prefix must be ASCII characters ‘R4’

Check character must be included in label

UPC-A

Number system must be included in label data.

Check digit must be included in label data and is assumed to be cor-
rect.

Prefix must be an ASCII character 'A' - total length including prefix
must be 13.

Example: 'A060992011187'.

UPC-A with 2-Digit Supplemental

Number system must be included in label data.

Check digit must be included in label data and is assumed to be cor-
rect.

Supplemental data is appended to base label.

Prefix must be an ASCII character 'A' - total length including prefix
must be 15.

Example: 'A06099201118712'.

Advertising
This manual is related to the following products: