Set-Up & Installation

Product Reference Guide

2-39

3. Hook the fingers of both hands into the lift handles. The first is

located along the inside of the front scanner wall, and the second is
behind the scanner hood, as shown in

Figure 2-23

.

4. Lower the unit into the counter opening, ensuring that none of the

cables are pinched, pierced or crimped.

5. Re-install the All Weighs™ Platter and verify that it is flush or just

below flush with the countertop. This is necessary to provide
smooth scanning from either direction. Make adjustments as needed
to align the platter with the counter by moving support rails up or
down, or consider installing screws in positions that will allow their
use in adjusting the unit’s position.

6. Once installation is complete, proceed with the

Operational Verifica-

tion

procedures that follow.

CAUTION

DO NOT attempt to lift the unit using the EAS Antenna, plastic edges, scale
frame, or any features other than the lift handles.

NOTE

Failure to install a scanner/scale in a stable and level position will inhibit
weighing, calibration and zeroing operations. The platter MUST make unob-
structed contact with all of its supports for proper weighing operation.