F-8

Magellan

®

9500

Codabar

•

Check character must be included in label data.

•

Label length including check character and excluding prefix charac-
ter must meet requirements imposed by the main scanner's fixed or
variable label length control for this symbology type.

•

Prefix must be an ASCII character '%'.

•

Start stop character sets must meet the matching requirement set
forth by the scanner configuration item

Codabar Start Stop Character

Match

.

•

Start stop character sets must be of the form ABCD/ABCD and
must be included in the label.

•

Example: '%s$99.95s' (the lower case ‘s’ at each end of the example
is a placeholder for the start stop character set).

Code 128

•

Prefix must be an ASCII character '#'.

•

Label length excluding prefix character must meet requirements
imposed by the main scanner's fixed or variable label length control
for this symbology type.

•

Function characters may be transmitted as a hexadecimal value 8x.
Where x correlates to function characters 1 thru 4 as follows:

•

x80 = function code 1

•

x81 = function code 2

•

x82 = function code 3

•

x83 = function code 4

•

For Code 128 programming labels the format is of the general form
'#/82nnnnn/r ' - /82 is hexadecimal 82 and /r is carriage return.

•

Example: '#Code_128.Test'.