Skip to step – Datalogic Scanning 9500 User Manual

Page 63

Advertising
background image

Set-Up & Installation

Product Reference Guide

2-35

4. Disconnect the Load Cell harness.

5. Move the Load Cell/Spider Assembly into position on the opposite

side of the scanner cavity and re-install the original screws. Torque
the screws evenly to 50 in-lb.

Figure 2-19. Locating the EAS Single-Antenna (Left-to-Right)

6. Route the Load Cell harness, re-bending it as indicated on the har-

ness, and reconnect.

7. Orient the EAS Antenna in the position indicated by

Figure 2-17

,

then route the antenna cable down through the unit’s side. Securely
attach the antenna using the screws provided.

8. Connect the antenna cable to the EAS Controller Box.

9. Re-install the platter.

This completes the EAS Single-Antenna location swapping procedure.

EAS Antenna

Product Flow

Product Flow

Load Cell/Spider

Assembly

Load Cell Harness

(bend for left-hand

scale installation)

The scale must be recalibrated upon completion of this proce-
dure, or upon completion of installation.

WARNING

DO NOT touch EAS Antenna coils inside of housing when in operation. Coils
generate over 500 VDC when activated.

LEGAL NOTE