Codabar

Check character must be included in label data.

Label length including check character and excluding prefix charac-
ters must meet requirements imposed by the main scanner's fixed or
variable label length control for this symbology type.

Prefix must be ASCII characters ']F0'.

Start stop character sets must meet the matching requirement set
forth by the scanner configuration item

Codabar Start Stop Character

Match

.

Start stop character sets s must be of the form ABCD/ABCD and
must be included in the label.

Example: ']F0s$99.95s' (the lower case ‘s’ at each end of the example
is a placeholder for the start stop character set).

MSI/Plessey

Check character must be included in label data.

Label length including check character and excluding prefix charac-
ters must meet requirements imposed by the main scanner's fixed or
variable label length control for this symbology type.

Prefix must be ASCII characters ']M0'.

Example: ']M0144769254'.

Code 93

Prefix must be ASCII characters ']G0'.

Label length excluding prefix characters must meet requirements
imposed by the main scanner's fixed or variable label length control
for this symbology type.

Example : ']G0Code93-test'.