Manual eas deactivation push button – Datalogic Scanning 9500 User Manual

Page 404

Advertising
background image

A-8

Magellan

®

9500

Manual EAS Deactivation Push Button

Using the programming bar codes contained in the Product Refer-
ence Guide (PRG) the button can be configured to operate always,
or only function when the scanner is enabled.

PRESS

DURATION

FUNCTION

COMMENT

Momentary

a

Manually initiates EAS
deactivation

Place the item with the EAS tag downstream

b

of the

horizontal scan window and push the button.

3 Seconds upon
EAS error

Allows scanner to resume
function despite EAS sys-
tem failure (non-fatal
error)

EAS Failure Mode is indicated

c

by:

- EAS LED blinks ON/OFF red, scanning disabled.
- FRU Status LED Indicator blinks ‘9’
- Error tone is sounded for one second
Upon pressing the button for 3 seconds, the scan-
ner will sound 3 high-pitched beeps, then resume
scan function. The EAS LED and FRU Status LED
will continue blinking as above, but at a slower rate
until EAS system function is restored.

a. For use in Coupled Mode only
b. “Downstream” in this case is defined as being the downstream side of the scan window from

the direction of product flow, or scanning direction.

c. If the EAS failure corrects itself, blinking will stop and the EAS LED will turn green.

Advertising
This manual is related to the following products: