3. The vertical scan window is held in place by two tabs each on its top

and bottom edges. To remove it, carefully push out on the top as
shown in

Figure 3-4

and lift it out. Carefully dispose of any dam-

aged glass.

Figure 3-4. Vertical Scan Window Removal/Replacement

4. Fully seat the new vertical scan window into the window channel

within its bottom retention tabs. Tilt the window in to engage the
two tabs at the top of the retainer and carefully snap the window to
secure it in place.

5. Clean both sides of the new vertical scan window using a paper

towel or lint free cleaning tissues dampened with a mild, water-
based glass cleaner. DO NOT use abrasive cleaners or pads.

6. Re-install the platter. Vertical scan window replacement is now com-

plete.