Flowcharts, Flowcharts -6 – Datalogic Scanning 9500 User Manual

Page 92

Advertising
background image

4-6

Magellan

®

9500

Flowcharts

The problem isolation flowcharts on the following pages allow you to
identify and troubleshoot problems with your system.

E__3

Flash, pause, 3
blinks, long pause,
repeat sequence.

Scale communication lost.
Internal scanner/scale prob-
lem.

Call technical support personnel;
report error.

E__4

Flash, pause, 4
blinks, long pause,
repeat sequence.

Scale module failure.

Call technical support personnel;
report error.

E__5

Flash, pause, 5
blinks, long pause,
repeat sequence.

Internal software fault.

Call technical support personnel;
report error.

Other Scale Reporting

- 0 -

Off

Cannot zero at power- up or
weight remains on scale for
more than 4 minutes or
weight has not returned to
zero between POS weight

requests

a

.

- Check debris chutes.
- Verify that the weigh platter moves
freely.
- Remove item(s) from scale
- Press Scale Zero Push Button

- for more information.

- If the scale still fails to zero, recali-
brate the scale.

a. This is a configurable feature.

Remote

Display

Scale Status

Lamp

Problem

Description

Action Required