3 automatic uplink power control, 4 data interfaces – Comtech EF Data CDM-550T User Manual

Page 114

Advertising
background image

CDM-550T Satellite Modem

Revision 3

Summary Of Specifications

MN/CDM550T.IOM

TURBO PRODUCT CODEC BER
(With two adjacent carriers, each
7 dB higher than desired)




For:

BER=10-6
BER=10-7
BER=10-8

Rate 3/4 (Q)
Guaranteed Eb/No:
(typical value in
parentheses)

3.9dB (3.5dB)
4.1dB (3.7dB)
4.3dB (4.0dB)

Rate 21/44 (B) / ½ (Q)
Guaranteed Eb/No:
(typical value in
parentheses)

2.8dB (2.5dB)
3.1dB (2.8dB)
3.3dB (3.0dB)

Rate 5/16 (B)
Guaranteed Eb/No:
(typical value in
parentheses)

2.3dB (2.0dB)
2.6dB (2.3dB)
2.8dB (2.5dB)

Buffer

Plesiochronous/Doppler buffer with selectable size of 512, 1024, 2048,
4096 or 8192 bits

Supports asymmetric operation - when buffer is clocked from Tx clock, Rx
and Tx rates do not need to be identical

Monitor Functions

• Eb/No

estimate

Corrected Bit Error Rate

• Frequency

offset

Buffer fill state

Coarse AGC voltage

14.3

Automatic Uplink Power Control

Operating Mode

Requires Framed mode for transport of Eb/No information from remote modem
(EDMAC can be enabled or disabled)

Target Eb/No range

0 to 9.9 dB at remote demod (default is 3.0 dB)

Max AUPC range

0 to 9 dB (default is 1 dB)

Monitor functions

Remote demod Eb/No
Tx power level increase
(front panel or via remote control interface)

14.4 Data

Interfaces

Built in

RS-422/RS-530 DCE (also supports X.21 DCE and DTE)
V.35 DCE
Synchronous RS-232
Asynchronous RS-232 (maximum data rate: 56 kbaud)
(Front panel selectable)

Pinout

Per RS-530 (25 pin ‘D’ type female)

Optional

G.703 T1/E1 plug-on interface (Comtech EF Data P/N: CIC-50)

14–4

Advertising