Comtech EF Data CDM-550T User Manual

Page 134

Advertising
background image

CDM-550T Satellite Modem

Revision 3

Remote Control

MN/CDM550T.IOM

15–18

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(note that all arguments are ASCII numeric codes, that is,

ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Retrieve next 5
unread Stored
Statistics

N/A

130 bytes

Query only
Unit returns the oldest 5 Stored Statistics which have not yet
been read over the remote control. Reply format:
{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body, where Sub-body=
AA.ABB.BC.CD.Dddmmyyhhmmss,
AA.A = Minimum Eb/No during sample period.
BB.B = Average Eb/No during sample period.
C.C = Max. Tx Power Level Increase during sample period.
D.D = Average Tx Power Level Increase during sample period.
ddmmyyhhmmss = date/time stamp.

If there are no new events, the unit replies with RNS* If there are
less than 5 statistics to be retrieved, the remaining positions are
padded with zeros.

N/A RNS?

RNS={CR}AA.A
BB.BC.CD.Ddd
mmyyhhmmss{C
R}AA.ABB.BC.C
D.Dddmmyyhhm
mss
{CR}AA.ABB.BC
.CD.Dddmmyyh
hmmss
{CR}AA.ABB.BC
.CD.Dddmmyyh
hmmss
{CR}AA.ABB.BC
.CD.Dddmmyyh
hmmss (see
description for
details of
arguments)

Retrieve Number
of unread Stored
Statistics

N/A 3

bytes,

numerical

Query only.
Unit returns the number of Stored Statistics which remain
unread, in the form xxx. Note: This means unread over the
remote control - viewing the stored events from the front panel
of the modem does not affect this value.

Example reply: NUS=198

N/A NUS?

NUS=xxx

(see

description for
details of
arguments)

Clear All Stored
Statistics

CAS= None

Command

only

Instructs the unit to clear all Stored Statistics
This command takes no arguments.

CAS= (message ok)

N/A

N/A

Local/Remote
Status

LRS=

1 byte, value of 0
or 1

Command or Query (Command only if S/W > 1.13)
As a query, returns the local/remote status of the unit, where:
0 = local
1= remote
When used as a comand, uses the same codes for an
argument.

Example: LRS=1 (unit is in remote mode)

LRS=
(message ok)

LRS?

LRS=x (see
description for
details of
arguments)

Serial Number

SNO=

4 bytes
numerical
0000 to 9999

Command portion is FACTORY USE ONLY.
Used to set or Query the units 4 digit serial number.
Unit returns its S/N, in the form xxxx.

Example: SNO=1765 (1

ST

4 DIGITS OF ESN – 9 DIGIT S/N)

SNO= (message ok)

SNO?

SNO=xxxx (see
description for
details of
arguments)

Advertising