15–8

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(note that all arguments are ASCII numeric codes, that is,

ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Tx Frequency

TFQ=

8 bytes

Command or Query.
Tx Frequency, 52 MHz to 88 MHz, (70 MHz band) or 104 MHz
to 176 MHz, (140 MHz band).
Resolution = 100Hz.
Example: TFQ=072.9876 (70 MHz option)
TFQ=148.0000 (140 MHz option)

Note: Querying ‘Options Fitted’ (using EID?) will indicate if the
unit is 70 MHz or 140 MHz IF band

TFQ= (message ok)
TFQ? (received ok,
but invalid arguments
found)
TFQ* (message ok, but
not permitted in current
mode)

TFQ? TFQ=xxx.xxxx

(same format
as command
arguments)

Tx
Data Rate

TDR=

8 bytes

Command or Query.
Tx Data rate, in kbps, between 2.4 kbps and 2048 kbps.
Resolution = 1 bps.

Example: TDR=2047.999 (which is 2047.999 kbps)

TDR= (message ok)
TDR? (received ok,
but invalid arguments
found)
TFQ* (message ok, but
not permitted in current
mode)

TDR?

TDR=xxxx.xxx
(same format
as command
arguments)

Tx Spectrum
Invert

TSI=

1 byte, value of 0
or 1

Command or Query.
Tx Spectrum Invert selection, where:
0 = Normal,
1 = Tx Spectrum Inverted
All other codes invalid.

Example:TSI=0 (which is normal)

TSI= (message ok)
TSI? (received ok, but
invalid arg. found)
TSI* (message ok, but not
permitted in current
mode)

TSI? TSI=x

(same format
as command
argument)

Tx
Scrambler

TSC=

1 byte, value of 0
or 1

Command or Query.
Tx Scrambler state, where:
0 = Off
1 = On (V.35 in transparent mode, synchronous in framed mode
All other codes invalid.

Example: TSC=1 (which is scrambler On)

TSC= (message ok)
TSC? (received ok,
but invalid argument
found)
TSQ* (message ok, but
not permitted in current
mode)

TSC? TSCS=x

(same format
as command
argument)

Tx Power Level

TPL=

4 bytes

Command or Query.
Tx Output power level between 0 and -20 dBm (minus sign
assumed). Example: TPL=13.4 (which is
-13.4 dBm)

TPL= (message ok)
TPL? (received ok,
but invalid arguments
found)
TPL* (message ok, but
not permitted in current
mode)

TPL?

TPL=xx.x
(same format
as command
arguments)

Tx Clock Source

TCK=

1 byte, value of
1,2 or 3

Command or Query.
Tx Clock source, where:
1 = Internal
2 = External
3 = Loop timed (use Rx satellite clock)
All other codes invalid.

Example: TCK=2 (which is External Clock)

TCK= (message ok)
TCK? (received ok,
but invalid argument
found)
TCK* (message ok, but
not permitted in current
mode)

TCK?

TCK=x
(same format
as command
argument)

Advertising