Comtech EF Data CDM-550T User Manual

Page 128

Advertising
background image

CDM-550T Satellite Modem

Revision 3

Remote Control

MN/CDM550T.IOM

15–12

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(note that all arguments are ASCII numeric codes, that is,

ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Eb/No Alarm
Point

EBA= 4

bytes,

numerical

Command or Query.
Eb/No alarm point, with a range of Eb/No between 0 and 16 dB.
Resolution 0.1 dB.

Example: EBA=12.3 (which is Eb/No = 12.3 dB)

EBA= (message ok)
EBA? (received ok,
but invalid arguments
found)

EBA? EBA=xx.x

(same format
as command
arguments)

Rx Buffer Size

RBS=

1 byte, value of
1,2,3,4 or 5

Command or Query.
Rx buffer size, where:
1 =

± 256 bits

2 =

± 512 bits

3 =

± 1024 bits

4 =

± 2048 bits

5 =

± 4096 bits

RBS= (message ok)
RBS? (received ok,
but invalid argument
found)
RBS* (message ok, but
not permitted in current
mode)

RBS? RBS=x

(same format
as command
argument)

Advertising