Comtech EF Data CDM-550T User Manual

Page 125

Advertising
background image

CDM-550T Satellite Modem

Revision 3

Remote Control

MN/CDM550T.IOM

15–9

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(note that all arguments are ASCII numeric codes, that is,

ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Tx Carrier On/Off
State

TXO=

1 byte, value of
0, 1, 2 or 3

Command or Query.
Tx Carrier On/Off state, where:
0 = Off due to front panel or rem. control command
1 = On
2 = Off due to ext H/W Tx Carrier Off command (not a valid
argument when used as a command) All other codes invalid.
3 = RTI (Receive/Transmit Inhibit)

Example: TXO=1 (which is Tx Carrier On)

TXO= (message ok)
TXO? (received ok, but
invalid argument found)
TXO* (message ok, but
not permitted in current
mode)

TXO? TXO=x

(Note that 2 is
not a valid
argument when
used as a
command)


Advertising