Comtech EF Data CDM-550T User Manual

Page 133

Advertising
background image

CDM-550T Satellite Modem

Revision 3

Remote Control

MN/CDM550T.IOM

15–17

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(note that all arguments are ASCII numeric codes, that is,

ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Output Filter
Mask

OFM=

1 byte, value of 0
or 1

Command or Query.
Output Filter mask, where:
0=Normal (Default)
1=Narrow

Example: OFM = 1 (Narrow)

OFM=(message ok)
OFM? (received ok, but
invalid argruments found)
OFM* (message ok, but
not permitted in current
mode)

OFM? OFM=x

(same format as
command
argument)

Retrieve next 5
unread Stored
Events

N/A

80 bytes

Query only
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body,
where Sub-body=ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Power on/off, or log cleared
5=Open Network
C is Fault Code numbers, as in FLT? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNE*

N/A RNE?

RNE={CR}ABCd
dmmyyhhmmss{
CR}ABCddmmy
yhhmmss{CR}A
BCddmmyyhhm
mss
{CR}ABCddmmy
yhhmmss{CR}A
BCddmmyyhhm
mss
(see description
for details of
arguments)

Retrieve Number
of unread
Stored Events

N/A 2

bytes,

numerical

Query only.
Unit returns the number of Stored Events which remain unread,
in the form xx. Note: This means unread over the remote control
- viewing the stored events from the front panel of the modem
does not affect this value. Example reply: NUE=98

N/A

NUE?

NUE=xx (see
description for
details of
arguments)

Clear All Stored
Events

CAE= None

Command

only

Instructs the unit to clear all Stored Events
This command takes no arguments.

CAE= (message ok)

N/A

N/A

Advertising