Config: tx, fec, rate) fec rate (turbo only) – Comtech EF Data CDM-550T User Manual

Page 44

Advertising
background image

CDM-550T Satellite Modem

Revision 3

Front Panel Operation

MN/CDM550T.IOM

If the Turbo Codec option is installed, the following menu will be displayed:

Select Viterbi, Sequential, Turbo or None, using the [

←] [→] arrow keys, then

press

ENTER.

(CONFIG: TX, FEC, RATE

)

FEC Rate

(Any FEC Type Except Turbo)


Select Rate 1/2, Rate 3/4 or Rate 7/8 encoding rate, using the [

←] [→] arrow

keys, then press ENTER.

Note: If BPSK is selected, only Rate 1/2 is permitted. A warning screen appears
if this sub-branch is entered when in BPSK mode.

If Turbo is selected, the following sub-menu will be displayed:

(CONFIG: TX, FEC, RATE) FEC Rate (Turbo Only)

Select Rate 3/4 (QPSK), Rate 21/44 (BPSK ONLY) Rate 5/16 (BPSK ONLY),
Rate 3/4 (OQPSK), or Rate 1/2 (Q) encoding rate, using the [

←] [→] arrow keys,

then press ENTER.

SELECT FEC TYPE: VITERBI
SEQ TURBO NONE (ENTER)


SELECT FEC ENCODER RATE:

1/2 3/4 7/8(PRESS ENT)

TX TURBO:3/4(Q) 21/44(B)

5/16(B) 3/4(OQ)1/2(Q)(ENT)

Turbo Rate 3/4 OQPSK

Incorporated by Version 1.19

Turbo Rate 1/2 QPSK

Incorporated by Version 1.24


Note: For further details, see Section 7 - ‘FEC Options’.