(ODU:)

ENABLE

ÆCONFIG Æ RECEIVER Æ LNA Æ FAULT- LOGIC

SELECT LNA FAULT LOGIC:

SUMMARY NO–SUMM (ENTER)


Select SUMMARY or NO SUMM using the [

←] [→] keys, then press <ENTER>. This

controls whether or not LNA fault will activate the SUMMARY FAULT RELAY.

D.2.2.1.1.3 (ODU:) ENABLE

Æ CONFIG Æ MISC (Miscellaneous)

KST MISC: AGC

REF-ADJUST (ENTER)


Select the desired ODU parameters for modification using the [

←] [→] keys, then press

<ENTER>.

(ODU:)

ENABLE

Æ CONFIG Æ MISC Æ AGC (Auto Gain Control)

SEL AGC MODE:

OFF ON BURST (ENTER)


Select either OFF, ON or BURST using the [

←] [→] keys, then press <ENTER>.

(ODU:)

ENABLE

Æ CONFIG Æ MISC Æ REF-ADJUST

EDIT INT REF ADJUSTMENT:

028 (PRESS ENTER)


Edit the INT 10MHz REF setting using the [

↑] [↓] keys, then press <ENTER>. The

value will scroll between 000 and 255.

Note: The INT REF is adjusted in the factory to be very accurate with the default setting
of 028. This parameter is made available to compensate for the long-term frequency drift
of the oscillator.