15.6.5

Bulk Commands

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(note that all arguments are ASCII numeric codes, that is,

ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Global
Configuration

MGC= 78

bytes,

with

numerical
entries, fixed
value entries,
and delimiters

Command or Query.
Global configuration of unit, in the form:
FFF.FFFFDDDD.DDDGRMVSPP.PCXfff.ffffdddd.dddgrmvswwct
t.tbIOTZAAAAAUEEEEBYYY.YYW, where:
FFF.FFFF = Tx Frequency - same as TFQ= (8 bytes)
DDDD.DDD = Tx Data Rate - same as TDR= (8 bytes)
G = Tx FEC Coding type - same as TFT= (1 byte)
R = Tx FEC Code Rate - same as TCR= (1 byte)
M = Tx Modulation - same as TMD= (1 byte)
V = Tx Spectrum Invert - same as TSI= (1 byte)
S = Tx Scrambler State - same as TSC= (1 byte)
PPPP = Tx Power Level - same as TPL= (4 bytes)
C = Tx Clock Source - same as TCK= (1 byte)
X = Tx Carrier Status - same as TXO= (1 byte)
fff.ffff = Rx Frequency - same as RFQ= (8 bytes)
dddd.ddd = Rx Data Rate - same as RDR= (8 bytes)
g = Rx FEC Decoding type - same as RFT= (1 byte)
r = Rx FEC Code Rate - same as RCR= (1 byte)
m = Rx Modulation - same as RMD= (1 byte)
v = Rx Spectrum Invert - same as RSI= (1 byte)
s = Rx De-scrambler - same as RDS= (1 byte)
ww= Rx Sweep Width - same as RSW= (2 bytes)
c = Rx Clock Mode - same as RCK= (1 byte)
tttt = Eb/No Alarm Point - same as EBA= (4 bytes)
b = Rx Buffer Size - same as RBS= (1 byte)
I = Unit Interface Type - same as ITF= (1 byte)
O =Unit Framing Mode - same as FRM= (1 byte)
T = Unit Test Mode - same as TST= (1 byte)
Z = Unit IF Impedance - same as IMP= (1 byte)
AAAAA = Alarm Mask - same as MSK= (5 bytes)
U= ODU Comms - same as ODU= (1 byte)
EEEE= EDMAC Slave address - same as ESA= (4 bytes)
B= AUPC enable - same as AUP= (1 byte)
YYYYYY = AUPC setup - same as APP= (6 bytes)
W =Stats log interval- same as SSI (1 byte)
Example:
MGC=074.56780064.0001720112.720082.65430
128.0002320116109.81211100000102361115.659

MGC= (message ok)
MGC? (received ok,
but invalid arguments
found)

MGC? MGC=FFF.FFFF

DDD.DDDRMVS
PP.PCXfff.ffffddd
.dddrmvswwctt.t
bIOTZAAAAAUE
EEEBYY
Y.YYW
(same format as
command
arguments)

15–23