Comtech EF Data CDM-550T User Manual

Page 138

Advertising
background image

CDM-550T Satellite Modem

Revision 3

Remote Control

MN/CDM550T.IOM

15–22

Parameter

Type

Command

(Instruction

Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(note that all arguments are ASCII numeric codes, that is,

ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Faults
and
Status

N/A

5 bytes,
first 3 bytes
alpha-numerical
4th and 5th
bytes, value of 0
or 1

Query only.
Unit returns the current fault and status codes for the Unit
(hardware), Tx Traffic and Rx Traffic, in the form abcde, where:
a = Unit fault status, b = Tx Traffic status,
c = Rx Traffic Status, d = Change in Fault Status since last poll
(0 = none, 1 = change), e = Change in Unit Configuration since
last poll (0 = none, 1 = change)
Unit faults:

0 = No faults
1 = Power supply fault, 5 volts
2 = Power supply fault , 12 volts
3 = Power supply fault, -5 volts
4 = Power supply fault, 18 volts
5 = Power supply fault, -12 volts
6 = RAM load fail
7 = Tx synthesiser lock
8 = Rx synthesiser
9 = Power cal Checksum error
A = FPGA main chain load fail
B = Turbo FPGA load fail

Tx Traffic status:

0 = Tx traffic OK
1 = No clock from terrestrial interface
2 = Tx FIFO slip
3 = AIS detected on incoming data
4 = AUPC upper limit reached

Rx Traffic status:

0 = Rx Traffic OK
1 = Demodulator unlocked
2 = AGC Alarm - signal level too high
3 = Frame sync lost (Reed-Solomon or EDMAC)
4 = Buffer Underflow
5 = Buffer Overflow
6 = AIS detected on incoming data
7 = Eb/No threshold exceeded

N/A FLT?

FLT=abcde
(see description
for details of
arguments

Advertising