Monit: stats) configure – Comtech EF Data CDM-550T User Manual

Page 70

Advertising
background image

CDM-550T Satellite Modem

Revision 3

Front Panel Operation

MN/CDM550T.IOM

interval, the average Eb/No will also show ‘LOSS’. (The display will show
‘LOSS,LOSS’.)

• If the measured values are greater than, or equal to 16.0 dB, the display

will show 16.0 dB.

• If AUPC is not enabled, the values of maximum and average TPLI will

both show ‘0.0'.


Examples:

08.0,13.5,2.5,1.8 means:
Minimum Eb/No observed in the measurement interval = 8.0 dB
Average Eb/No observed in the measurement interval = 13.5 dB
Maximum TPLI observed in the measurement interval = 2.5 dB

Average TPLI observed in the measurement interval = 1.8 dB


LOSS,04.5,0.0,0.0 means:
There was a loss of demod lock during the measurement interval
Average Eb/No observed in the measurement interval = 4.5 dB
Maximum TPLI observed in the measurement interval = 0 dB
Average TPLI observed in the measurement interval = 0 dB
(Which indicates no AUPC activity, or that AUPC is disabled.)

If the user selects CLEAR, the statistics log is cleared, and the user is taken
directly back to the previous menu.

If the users selects CONFIGURE, the following sub-menu is displayed:

(MONIT: STATS) CONFIGURE

The user is prompted to enter the logging interval (the period of time over which
the statistics will be measured), using the [

↑] [↓] arrow keys, then press ENTER.

Setting this to a value of 00 disables the feature (no logging).

The user can choose 10, 20, 30, 40, 50, 60, 70, 80, or 90 minutes.

If AUPC is selected, and the modem is not in Framed mode, the following sub-
menu is displayed:


LOGGING INTERVAL:90 MINS

(SET 00 TO DISABLE)(ENT)

6–34