CDM-550T Satellite Modem

Revision 3

Front Panel Operation

MN/CDM550T.IOM

6.2.3.4.3

(CONFIG: REMOTE

Æ BAUD)

If BAUD RATE is selected:

Edit the baud rate of the remote control bus, connected locally to the M&C computer. The value
is changed using the [

↑] [↓] arrow keys. The user should then press ENTER.

Values of 300, 1200, 2400, 4800, 9600 and 19200 baud are possible.

Note: The asynchronous character format is FIXED at: 8 data bits, 1 stop bit, no parity (8-N-1).


EDIT LOCAL BUS BAUDRATE:

19200 BAUD (PRESS ENTER)

6.2.3.4.4

(CONFIG: REMOTE

Æ INTFC)

If INTERFACE is selected:

Select RS-232, RS-485 (2-wire), or RS-485 (4-wire), using the [

←] [→] arrow keys, then press

ENTER.

At this point the user will be further prompted to enter the bus address.

In RS-232 mode the bus address is fixed at 0, and the following screen will be displayed:

(CONFIG: REM

Æ INTFC Æ ADDR) RS232 BUS ADDRESS

However, if either RS-485 mode is selected, the user will be further prompted:


ELECT. INTERFACE: RS232

RS485-2W RS485-4W (ENT)


IN RS232 MODE THE BUS

ADDRESS IS FIXED AT 0000

6–21