Figure c-6 vms server properties, traps tab – Comtech EF Data VMS v3.12.x Vipersat User Manual
Page 421
Advertising

Appendix
C -
Redundancy
C-11
MN/22156, rev 12
VMS Redundancy
NOC, for example.
Click the Traps tab, shown in figure C-6, to display the existing SNMP
Manager traps. Use the Insert, Modify, and Remove buttons to add new
traps and modify or remove existing traps. Refer to Appendix D, “SNMP
Traps”, for detailed information on the SNMP Manager.
Figure C-6 VMS Server Properties, Traps Tab
6. When finished, click the OK button to save the server properties settings.
7. Repeat steps 2 through 6 for each VMS server in the redundancy group.
8. Place the VMS server with the highest redundancy priority into the active
state:
Connect the console to the server with the highest priority and select the
Activate command from the VMS Server drop-down menu.