MX/DDC-100 Field Unit Installation and Maintenance FCD LMENIM2329-01 – 03/11

flowserve.com

System Integrator Tasks

Deliverable

From

To

Comments

Specification

Engineer

S.I

Detail functionality of system

Schedule

Contractor

S.I.

Production Schedule

Manuals

Limitorque

S.I.

Manuals for DDC-100 Operation:
• LMAIM4019 Direct-to-Host Programming Guide
• LMAIM1329 Accutronix Installation and Operation for MX-DDC Field Unit
• LMAIM4029 DDC-100 UEC Field Unit (Modbus) Installation and Operation

Manual

• LMAIM4030 DDC-100 UEC Field Unit Installation and Commissioning

Manual

• LMAIM4022 DDC-100 UEC Field Unit Wiring and Startup Guidelines
• Modicon Modbus Protocol Reference Guide PI-MODBUS-300 Rev. G

(available from Modicon)

Hardware for

system development Contractor

S.I.

Hardware may include: DDC-100 Field Units, RS-232/485 converters

Fourth-Party

Hardware/Software

Component

supplier

S.I.

Modbus interface modules, Modbus drivers, non-Limitorque converters, or

surge suppression

Actuator

Contractor

S.I.

Availability of DDC-100 Field Unit for testing developed application software

Site Preparation

Contractor

S.I.

Complete actuator or field unit installation. Provide actual (as installed) site

loop diagram to System Integrator

Operational System

S.I.

Contractor

Software only (code) or Hardware and Software (hardware and code)

Documentation

S.I.

Contractor

System Operation and Maintenance Manuals, Operational characteristics of

system, Network Addresses to equipment tag names

Engineer Tasks

Deliverable

From

To

Comments

Specification

End-user

Engineer

Site and system requirements

Schedule

End-user

Engineer

Production Schedule. Completion dates

Sales Support

Limitorque

Engineer

Information on Limitorque products

Manuals

Limitorque

Engineer

Manuals for DDC-100 Operation:
• LMAIM4019 Direct-to-Host Programming Guide
• LMAIM1329 Accutronix Installation and Operation for MX-DDC Field Unit
• LMAIM4029 DDC-100 UEC Field Unit (Modbus) Installation and Operation

Manual

• LMAIM4030 DDC-100 UEC Field Unit Installation and Commissioning

Manual

• LMAIM4022 DDC-100 UEC Field Unit Wiring and Startup Guidelines
• Modicon Modbus Protocol Reference Guide PI-MODBUS-300 Rev. G

(available from Modicon)

Project

Specification

Engineer

Contractor, S/I,

OEM,Limitorque Provide operational specifications for all equipment and service providers

Project

Responsibility

Engineer

Contractor

Define which supplier is responsible for each portion of project

P&ID

Engineer

Contractor

Detailed layout and instructions for building site. Information should include

actuator tag names, required data points from actuator, field unit, and field

wiring

Site Electrical

and electronics

Engineer

Contractor

Detail site electrical requirements, cable type, layout, and locations. Voltages

available for equipment

Loop Drawings

Engineer

Contractor

Detail cable routings from Host to each field device. This defines how the

network cable is to run throughout the facility