Chapter 7: View

A54-3000-100 A

81

A

PCON

, Inc.

SFP Alarms

Indicates operational status of SFP temperature, power, and
received signal. Checks the transmit signal only if Automatic
Transmitter Disable is set to

TX

on

when

no

RX

. For details about

this option, see

Properties

on page 133.

Green: The SFP is functioning within normal thresholds.
Flashing red: One or more SFPs have exceeded the alarm

threshhold defined by the SFP manufacturer. If this occurs, the
switch also emits an audible alarm. To determine which SFP(s)
and what alarm s encountered problems, click the field label to
display the

Alarms

screen. For details about this screen, see

page 61.

Message

The system message, a message supplied by the administrator.
Clicking the Edit link, viewable only by users with Administrator
permission privileges and located to the right of Switch Name,
displays the

Login Message

screen where you can change the

system message. For details about this screen, see page 140.
Note: You can also access this screen by selecting
Data>Message.