Using the mastering compressor, 9 – mixdown and mastering – Teac DP-008EX User Manual

Page 67

Advertising
background image

TASCAM DP-008EX

67

9 – Mixdown and mastering

3. After making the settings, press the F1 [BACK]

button to return to the

MASTERING

screen.

4. The

EQ

item on the

MASTERING

screen shows

whether the mastering equalizer is ON or OFF.

Using the mastering compressor

You can use either a single-band or multiband

mastering compressor.
Since using a multi-brand compressor allows you

to separate the low, medium and high frequency

bands of a stereo master track and independently

process them with different settings, you can adjust

the overall sound pressure balance. By doing this, you

can suppress unwanted peaks, raise the overall gain

to increase the sound pressure and achieve a sound

with greater impact.
1. When in

MASTERING

mode, press the F2 [COMP]

button to open the

MASTERING COMP

screen.

2. Press the F3 [LIB] button to open the

MASTERING

COMP

library.

COMPx3

as the

TYPE

indicates a multiband

compressor.

COMPx1

indicates a single-band

compressor.

3. Use the data wheel to select (highlight) a preset

in the library, and press the F4 [EXEC] button.

After loading the preset, the

MASTERING COMP

screen reopens.

4. Press the F4 [PARM] button to open the

MASTERING COMP

parameter setting screen.

Multiband compressor example

Single-band compressor example

At this time, the selected band is shown in the

upper left.

When using a multiband compressor, press the

F2 [BAND] button to cycle through the bands

that can be set in order:

LOW BAND

w

MID

BAND

w

HIGH BAND

(w

LOW BAND

).

When using a single band compressor, press the

F2 [BAND] button to switch between

BAND

and

A.MAKEUP

screens.

5. Use the F3 [5] and F4 [b] buttons to select

(highlight) a parameter you want to set, and use

the DATA wheel to adjust its value.

When a setting is at its default value,

i

appears to

the right of the value.

The ranges for each parameter are as follows.
THRSHLD

Set the threshold value that causes the

compressor to activate when exceeded.
Range: -32dB (default) – 0dB

RATIO

Set the compression ratio.
Options: 1.0:1, 1.1:1, 1.3:1, 1.5:1, 1.7:1, 2.0:1, 2.5:1,

3.0:1, 3.5:1, 4.0:1, 5.0:1, 6.0:1, 8.0:1, 16.0:1, inf:1

LEVEL

Set the output level.
Options: -20dB – +20dB

6. Press the F2 [BAND] button when using a

multiband compressor to change the frequency

band to

LOW BAND

,

MID BAND

or

HIGH BAND

,

and set the parameters for that band.

Press the F2 [BAND] button when using a single-

band compressor to show the

A.MAKEUP

setting.

Turn the automatic makeup function ON or OFF.

When ON, the unit will automatically adjust

the volume after compression so that it is not

decreased.

When this setting is at its default value,

i

appears

to the right of the value.

Advertising