Item

Description

tc-protection

Select whether to enable TC-BPDU guard.
When receiving topology change (TC) BPDUs, the device flushes its forwarding

address entries. If someone forges TC-BPDUs to attack the device, the device will
receive a large number of TC-BPDUs within a short time and frequently flushes its

forwarding address entries. This affects network stability.
With the TC-BPDU guard function, you can prevent frequent flushing of forwarding

address entries.
H3C does not recommend you to disable this function.

tc-protection threshold

Set the maximum number of immediate forwarding address entry flushes the device
can perform within a certain period of time after receiving the first TC-BPDU.

Configuring MSTP on a port

1.

Select Network > MSTP from the navigation tree.

2.

Click the Port Setup tab to enter the page for configuring MSTP on ports.

Figure 171 MSTP configuration on a port

3.

Configure MSTP for ports as described in

Table 63

.

4.

Click Apply.

Table 63 Configuration items

Item

Description

STP

Select whether to enable STP on the port.