Rmon configuration example, Network requirements, Configuration procedure – H3C Technologies H3C WX5500E Series Access Controllers User Manual
Page 98

88
Figure 79 Log
3.
View log information for all event entries.
In this example, event 1 has generated one log, which is triggered because the alarm value
(11779194) exceeds the rising threshold (10000000). The sampling type is absolute.
RMON configuration example
Network requirements
As shown in
, create an entry in the RMON Ethernet statistics table to gather statistics on
GigabitEthernet 1/0/1 with the sampling interval being ten seconds, and perform corresponding
configurations so that the system logs the event when the number of bytes received on the interface more
than 1000 or less than 100.
Figure 80 Network diagram
Configuration procedure
1.
Configure RMON to gather statistics for GigabitEthernet 1/0/1:
a.
From the navigation tree, select Device > RMON.
The Statistics tab page appears.
b.
Click Add.
The page in
appears.
c.
From the Interface Name list. select GigabitEthernet1/0/1.
d.
In the Owner field, enter user1.
e.
Click Apply.