Configuring a history entry

1.

From the navigation tree, select Device > RMON.

2.

Click the History tab.
The History tab page appears.

Figure 71 History entry

3.

Click Add.
The page for adding a history entry appears.

Figure 72 Adding a history entry

4.

Configure a history entry, as described in

Table 26

.

5.

Click Apply.

Table 26 Configuration items

Item Description

Interface Name

Select the name of the interface on which the history entry is created.

Buckets Granted

Set the capacity of the history record list corresponding to this history entry (the
maximum number of records that can be saved in the history record list).
If the current number of the entries in the table has reached the maximum number, the

system deletes the earliest entry to save the latest one. The statistics include total
number of received packets on the current interface, total number of broadcast

packets, and total number of multicast packets in a sampling period.