Removal and Installation Procedures

Profile LVS Event Management System Instruction Manual

9-21

1. Open the operation panel. Refer to Procedures for Operation Panel on

page 9–13.

2. Use the long-nose pliers to disconnect the two cables going to the power

switch, and the ground cable connected to the bottom of the chassis.

3. Use the 2.0 mm hex wrench to remove the two screws securing the RFI filter

to the rear of the Live Controller.

4. Remove the RFI filter completely.

RFI Filter

Power Switch

RSĆ422 Cable (W005) with Connector

going to J140 on the CPU board.

RSĆ422 Cable (W006) with Connector

going to J141 on the CPU board.

To Power Switch

To Chassis Ground

From RFI Filter

To CP2 on the

Power Supply

Chassis Ground

Nut M3 7MM,

HEX

Figure 9-11: Power Switch, RFI Filter and RSĆ422 Connectors Removal (Inside View)

RFI Filter

Advertising