Grass Valley NV9648 v.1.1 User Manual

Page 40

Advertising
background image

30

Configuration

NV9648 Panel Configuration Page(s)

Enable Destination Lock.

Check ‘Enable Destination Lock’ so that any ‘Destination Lock’ button on the panel will func-
tion.

Enable Destination Protect.

Check ‘Enable Destination Protect’ so that any ‘Destination Protect’ button on the panel will
function.

Source Master Default.

Makes a machine control source the controlling device (or master device) by default. Other-
wise, the destination is the master by default. (The option is specifically for use with NV9000
series machine control routers.)

“Source is master” is used for duplication, or broadcast routing, on a machine control level.
“Destination is master” is for machine-to-machine editing.

Hide sources not configured on this panel.

Causes the names of source devices that are not presently configured for this particular
panel to be effectively hidden. When another panel changes the source to one not config-
ured for this panel, this panel displays asterisks instead.

Jump to multi-dest selection when switching to XY.

Makes the currently selected multi-destination device the current destination when you
switch from MD mode to X-Y mode.

The X-Y destination shown will be the default destination when the panel is in MD “hold”
mode and multiple destinations are selected

if a default destination is specified in the

configuration. Otherwise, no destination will be selected.

Flip-flop source and preset after take.

Swaps the preset source and the currently routed source for this destination after a take.

Enable force release.

Allows operators to execute a force release.

Jump back after source selection.

After you make a source selection, the panel reactivates the default button page.

Jump back after take.

After you press a ‘Take’ button, the panel reactivates the default button page.

Jump back after destination selection.

After you make a destination selection, the panel reactivates the default button page.

Jumping back to the default page is usually helpful, but in some configuration designs,
might not be. You can design your panel configuration to take advantage of the jump-
back behavior.

Src/dst immediate take.

A ‘Src/Dst’ button connects a source to a destination. When this box is checked (as it is in the
default NV9648 configuration) the button performs an immediate take. When the box is
clear, the button sets up the take and the operator must press a ‘Take’ button to complete
the take.