3 sunny central 720he, Sunny central 720he – SMA SC 500HE-20 Installation User Manual
Page 68
14 Technical Data
SMA Solar Technology AG
68
SCxxxHE-20-IA-IEN111210
Installation Manual
Power consumption
Dimensions and weight
Efficiency
Ambient conditions
14.3 Sunny Central 720HE
Input values
Self-consumption in operation
< 1 500 W
Standby consumption
< 100 W
External auxiliary supply voltage
3 x 230 V, 50 Hz / 60 Hz
Width x height x depth
2 404 mm x 2 093 mm x 937 mm*
* Without anchorage bracket in base, incl. spreader beam, depth incl. all attached components
Weight
1 670 kg
Maximum efficiency
98.7%
Euro-eta
98.5%
CEC-eta
98.5%
Degree of protection*
* As per DIN EN 60529
IP 21
Operating temperature range
–20°C ... +50°C
Humidity
15% … 95%
Fresh air consumption
3 000 m³/h
Maximum altitude above sea level, MSL
2 000 m
MPP voltage range
525 V
DC
… 820 V
DC
Maximum DC voltage*
* Optional 1 100 V
1 000 V
DC
Maximum DC current
1 400 A
DC
Number of DC inputs
9