Node 260 (Dual Port Ram) Assignments - Continued

Appendices

97

Node, Channel and Subchannel Assignments

9/15/93

601

~

NUMO

Dn-01 (MOTOR BASE SPEED)

1750

RPM

602

~

NUMO

Dn-02 (MOTOR MAXIMUM SPEED)

1750

RPM

603

~

NUMO

Dn-03 (NUMBER OF MOTOR POLES)

4

~

604

~

NUMO

Dn-04 (MOTOR NO LOAD VOLTAGE)

170/340

VAC

605

~

NUMO

Dn-05 (MOTOR RATED PRIMARY CURRENT)

AAC

606

~

NUMO

Dn-06 (RATED SLIP FREQUENCY)

1.00

HZ

607

~

NUMO

Dn-07 (EXCITATION CURRENT REFERENCE)

30.0

%

608

~

NUMO

Dn-08 (PRIMARY RESISTANCE, USED WITH OPT TRQ

2.0

%

BOARD)

609

~

NUMO

Dn-09 (LEAKAGE COEFFICIENT, USED WITH OPT TRQ

20.00

%

BOARD)

610

~

NUMO

Dn-10 (MOTOR IRON LOSS)

2.0

%

611

~

NUMO

Dn-11 (MOTOR MACHINERY LOSS)

0.5

%

612

~

NUMO

Dn-12 (SECONDARY CIRCUIT TIME CONSTANT)

100

MSEC

613

~

NUMO

Dn-13 (LEAKAGE SAT COEF, USED WITH OPT TRQ

1.20

~

BOARD)

614

~

NUMO

Dn-14 (ROTOR HEAT GAIN)

0.00

~

615

~

NUMO

Dn-15 (ROTOR HEAT TIME CONSTANT)

30

MIN

616

~

NUMO

Dn-16 (IRON CORE SATURATION COMP

0.5

~

COEFFICIENT 1)

617

~

NUMO

Dn-17 (IRON CORE SATURATION COMP

0.75

~

COEFFICIENT 2)

618

~

NUMO

Dn-18 (MOTOR OVERHEAT TEMPERATURE)

120 ◆

°C

CHAN

SUB

PAC

INITIAL

UNITS

CHAN

BLOCK

DESCRIPTION

VALUE

TYPE

◆ -Initial value dependent on setting of Sn-02. Value shown is for Sn-02 setting of FFF hex.