background image

Appendices

79

VCM Motor/PG Connection

9/15/93

+12V (200mA)

1

White

Red

0V

2

Black

Black

A+

3

Red

Yellow

A–

4

Green

Wht/Yel

B+

5

Brown

Blue

B–

6

Yellow

Wht/Blue

SHIELD

7

Shield

Green

TB1

EPC

BEI

FUNCTION

TERMINAL

MODEL 755A

(1)

MODEL E25

Table 15. TB1 - PG Connection

CONNECTOR

FUNCTION

TERMINAL

WIRE

NO.

ARRANGEMENT

(2)

SIZE

Table 16. Connectors on PG Card

CA1

For Pulse
Generator

CA2

For Pulse
Monitor

18 GA

(0.75 mm2)

18 GA

(0.75 mm2)

(1) For PG, EPC Model 755A (provided as standard), Orange and Blue

wires are not used.

1 2 3

4 5

6 7 8

6 7 8

4 5

1 2 3

Pulse Generator connections are shown in the following tables.

(2) Top view (from pin connections).