Node, Channel and Subchannel Assignments

9/15/93

Every device in a MicroTrac system is identified with a Node number, a Channel
number, and a Subchannel number, regardless of whether the device uses the
Local Area Network or not. These identifiers have different significance for each
device and some devices may not need all three fields to provide a unique
identification. This appendix lists each device type relating to the VCD 723, and
describes the significance of each field for that device.

Node, Channel

and Subchannel

Assignments

VCD 723

Constants

CN-09 Settings
CN-09 sets the digital tach pulses per revolution. This is normally set for either
1024 or 2500 PPR depending upon the type of tach used on the motor.

DN-01 thru DN-18 Settings
DN-01 thru DN-18 set the motor constants per the following tables:

Dn-01

MOTOR BASE SPEED

1750

RPM

Dn-02

MOTOR MAXIMUM SPEED

1750

RPM

Dn-03

NUMBER OF MOTOR POLES

4

~

Dn-04

MOTOR NO LOAD VOLTAGE

PER TABLE

VAC

Dn-05

MOTOR RATED PRIMARY CURRENT

PER TABLE

AAC

Dn-06

RATED SLIP FREQUENCY

PER TABLE

HZ

Dn-07

EXCITATION CURRENT REFERENCE

PER TABLE

%

Dn-08

PRIMARY RESISTANCE, USED WITH OPT TRQ BOARD

PER TABLE

%

Dn-09

LEAKAGE COEFFICIENT, USED WITH OPT TRQ BOARD

PER TABLE

%

Dn-10

MOTOR IRON LOSS

PER TABLE

%

Dn-11

MOTOR MACHINERY LOSS

PER TABLE

%

Dn-12

SECONDARY CIRCUIT TIME CONSTANT

PER TABLE

MSEC

Dn-13

LEAKAGE SAT COEF, USED WITH OPT TRQ BOARD

1.20

~

Dn-14

ROTOR HEAT GAIN

0.00

~

Dn-15

ROTOR HEAT TIME CONSTANT

30

MIN

Dn-16

IRON CORE SATURATION COMP COEFFICIENT 1

0.5

~

Dn-17

IRON CORE SATURATION COMP COEFFICIENT 2

0.75

~

Dn-18

MOTOR OVERHEAT TEMPERATURE

155

°C

CONSTANT

DESCRIPTION

INITIAL VALUE

UNITS