Yaskawa VCD 723 User Manual

Page 68

Advertising
background image

4

Troubleshooting/Maintenance

62

Troubleshooting Flowcharts

9/15/93

Chart 3. Motor Does Not Rotate At Set Speed

CORRECT MOTOR FOR

USE WITH DRIVE?

YES

CONSULT MAGNETEK
ABOUT MOTOR
SELECTION.

NO

PROPER CONNECTIONS

FROM VCD 723 TO

MOTOR AND PG?

NO

CHECK CONNECTIONS
FOR PROBLEM AND
REPAIR.

YES

PROPER SPEED

REFERENCE INPUT?

PER PAC DIAGRAM.

NO

CHECK EXTERNAL
CIRCUITS FOR
PROBLEM AND
REPAIR.

YES

CHECK PARAMETER

SETTINGS PROPER
FOR APPLICATION?

NO

NO

CHECK SETTINGS;
REPROGRAM
AS REQUIRED.

YES

IS PG

OUTPUT SIGNAL

NORMAL?

IS PG

POWER SUPPLY

NORMAL?

YES

YES

NO

EXCESSIVE

MECHANICAL SYSTEM

CHATTER?

YES

CHECK FOR
PROBLEM IN MOTOR,
MECHANICAL SYSTEM
OR BRAKE.

CONSULT
MAGNETEK.

NO

CONSULT
MAGNETEK.

Advertising