6 switch settings – Yaskawa MP2000 Series User Manual

Page 13

Advertising
background image

Page 13

MP2000.02, 1/18/2011

Data subject to change without notice

Yaskawa America, Inc.

1.6 Switch Settings

1.6.1 SW 1 Settings




Name Status Operation

Mode

Function

Default

BRS0

BSR0:ON BSR1:ON 4M

BSR0:ON BSR1:OFF 2M

BSR0:OFF BSR1:ON 1M

BSR0:OFF BSR1:OFF 0.5M

PCLINK Baud Rate Setting

ON

BRS1

ON

SBRS

ON 19200

bps

Serial Port Baud Rate Setting

OFF

OFF 9600

bps

HOLD

ON Holding

Mode

Link Data Status at Fault Settings

OFF

OFF CLEAR

Mode

INIT

ON

Hardware Switch

Enabled

Baud Rate, Station Number Setting

Selection

OFF

OFF

Software Settings

Enabled

TEST

ON TEST

Mode

Run Mode Selection

OFF

OFF

Normal Operation Mode

1.6.2 Rotary Switch

Name Status

Operation

Mode

Default

Notes

ADRS X10

0-3

Station Address (10 Digits)

0

Station Address 1~32

Other settings not possible

ADRS X1

0-9

Station Address (1 Digit)

1

The status of each station is enabled only in a power ON state. (Changes after power ON will not be detected.)