Yaskawa MP2000 Series User Manual

Page 35

Advertising
background image

Page 35

MP2000.02, 1/18/2011

Data subject to change without notice

Yaskawa America, Inc.

(2)

Receive Message Function

*The CH-NO 1~4 are for message transmission between PCLINKs, and 5 is for reception from the MEMOBUS
port.

Function Name

MSG-RCV

Function

The messages are received from the counterpart station on the line designated in the transmission device

type. Multiple protocol types are supported.

Hold the execution command (EXECUTE) until COMPLETE or ERROR go "ON".

Transmission Device: PC-LINK

Protocol: MEMOBUS, non-procedural

Function

Definition

I/O Definition

No.

Name

I/O

Designation

Content

Input Items

1

EXECUTE

B-VAL

Receive Message Command

2

ABORT

B-VAL

Message Reception Forced Stop Command

3

DEV-TYP

I-REG

Transmission Device Classification

PC-LINK=3

4 PRO-TYP I-REG

Transmission

Protocol

MEMOBUS=1, Non-procedural 1=2, Non-procedural 2=3

5 CIR-NO

I-REG

Circuit

Number

PC-LINK = 1~8

6

CH-NO

I-REG

Transmission Buffer Channel Number

PC-LINK = 1~5

7

PARAM

Address Input

Set Data Lead Address

(MW, DW)

Output Items

1

BUSY

B-VAL

During Message Reception

2

COMPLETE

B-VAL

Message Reception Completed

3 ERROR

B-VAL

Error

Generation