3 message functions – Yaskawa MP2000 Series User Manual

Page 33

Advertising
background image

Page 33

MP2000.02, 1/18/2011

Data subject to change without notice

Yaskawa America, Inc.

4.2.3 Message

Functions

The message function specifications during PC-LINK use are shown below.

(1) Message Transfer Function

Function Name

MSG-SND

Function

The messages are transmitted to the counterpart station on the line designated in the transmission device

type. Multiple protocol types are supported.

Hold the execution command (EXECUTE) until COMPLETE or ERROR go "ON".

Transmission Device: PC-LINK

Protocol: MEMOBUS, non-procedural

Function

Definition

I/O Definition

No.

Name

I/O

Designation

Content

Input Items

1

EXECUTE

B-VAL

Message Transmission Command

2

ABORT

B-VAL

Message Transmission Forced Stop Command

3

DEV-TYP

I-REG

Transmission Device Classification

PC-LINK=3

4 PRO-TYP I-REG

Transmission

Protocol

MEMOBUS=1, Non-procedural 1=2, Non-procedural 2=3

5

CIR-NO

I-REG

Circuit Number: Sets the PCLINK-01 circuit number.

PC-LINK = 1~8

6

CH-NO

I-REG

Transmission Buffer Channel Number

PC-LINK = 1~4

7

PARAM

Address Input

Set Data Lead Address

(MW, DW)

Output Items

1

BUSY

B-VAL

During Message Transmission

2 COMPLETE

B-VAL

Message

Transmission

Completed

3 ERROR

B-VAL

Error

Generation

*Although the CH-NO can be set up to 5, 1~4 will be used as the MSG-SND function. CH5 can only be used by the
MSG-RCV.