User’s Manual of LRP-822CS

335

The page includes the following fields:

Object

Description

Mode

Allows user to enable or disable per port PD Alive Check function. By default, all

ports are disabled.

Ping PD IP Address

This column allows user to set PoE device IP address for system making ping to the

PoE device. Please note that the PD’s IP address must be set to the same network

segment with the PoE Switch.

Interval Time (10~300s)

This column allows user to set how long system should issue a ping request to PD

for detecting whether PD is alive or dead. Interval time range is from 10 seconds to

300 seconds.

Retry Count (1~5)

This column allows user to set the number of times system retries ping to PD.

For example, if we set count 2, it means that if system retries ping to the PD and the

PD doesn’t response continuously, the PoE port will be reset.

Action

Allows user to set which action will be applied if the PD is without any response. The

WGSW-48040HP PoE Switch offers the following 3 actions:

PD Reboot: It means system will reset the PoE port that is connected to the
PD.

PD Reboot & Alarm: It means system will reset the PoE port and issue an
alarm message via Syslog, SMTP.

Alarm: It means system will issue an alarm message via Syslog, SMTP.

Reboot Time (30~180s)

This column allows user to set the PoE device rebooting time as there are so many

kinds of PoE devices on the market and they have a different rebooting time. The

PD Alive-check is not a defining standard, so the PoE device on the market doesn’t

report reboot done information to the PoE Switch. Thus, user has to make sure how

long the PD will take to finish booting, and then set the time value to this column.

System is going to check the PD again according to the reboot time. If you are not

sure of the precise booting time, we suggest you set it longer.

Buttons

: Click to apply changes.