13 standard settings, Smart combi, Operation – Henny Penny SMART COMBI FM05-061-A User Manual

Page 58

Advertising
background image

3.

Use C o m b i D i a l ( 9 ) to enter the password “111”.

4.

Use C o m b i D i a l ( 9 ) to select the “Service water volume” menu.

5.

Set the water volume (in 100 litre increments) with C o m b i D i a l ( 9 ) .

4.13 Standard settings

The unit is already pre-configured when delivered.

The values listed in the following table can be adjusted individually (see

Chapter “Changing standard settings”, Page 57

).

Explanation

Possible settings

Pre-set value

Parameters

No.

Changeover summer time/winter time
is automatic. Date format: Parameter
144

Time/date

The operator's
local time

Time/date

000

Temperature display in °F is irrespective
of the system language.

°C/°F

in °C

Temperature reading

006

On: At the end of the cooking time the
lighting flashes in addition to the
acoustic signal sounding. It flashes as
long as the signal sounds.

On/off

On

Lighting flashes

023

Increase the preheat factor for full loads
of large masses (roasts, loaves of
bread) to prevent the temperature from
falling too much.

0–30 %

15

Preheat factor %

082

Applies for external water preparation
systems and only for the soft water
connection.

See

Chapter “Set service interval water

volume”, Page 57

for further informa-

tion.

0–90000 l in 100 l in-
crements

0

Service water volume

076

DD = day

MM = month

JJJJ = year

DD.MM.YYYY

YYYY/MM/DD

MM/DD/YYYY

DD.MM.YYYY

Date format

144

Free: you can change,delete or save
programs

Blocked: you may not change,delete
or save programs. But you may
make changes during the cooking
process.

Fully blocked: No changes are pos-
sible in the SmartMenu program
memory or during the cooking pro-
cess.

Free

Blocked

Fully blocked

Free

SmartMenu program
memory

097

Set “fan cycle operation”. The temperat-
ure in the cooking chamber can be kept
to 14 °C (57.2 °F) for 6 h by placing an
ice block in the bottom drawer.

On/off

Off

Time delay fan

032

Global Foodservice Solutions