Table 5-62, Table 5-63 – Maxtor ATLAS 10K III User Manual
Page 111
SCSI Description
Maxtor Atlas 10K III
5-47
7PKV #VVGPVKQP %QPFKVKQP 2CIG J
The Unit Attention Page is used to enable or disable the generation of Unit Attention
Conditions. The Unit Attention Condition Page format and field descriptions are
described in Table 5-62 and Table 5-63 respectively.
Table 5-62
Unit Attention Condition Page (Page 0)
Table 5-63
Unit Attention Condition Page (Page 0)
Bit
$[VG
0
PS
Rsvd
Page Code (00h)
1
Page Length (02h)
2
Reserved
DUA
Reserved
3
Reserved (00h)
(KGNF
&GHCWNV 8CNWG
&GUETKRVKQP
PS
1
Parameters Savable. This bit is only used with the MODE
SENSE command. A returned value of 1 indicates that the tar-
get is capable of saving the page in a non-volatile, vendor-
specific location. The bit is reserved with the MODE SELECT
command.
DUA
0
Disable Unit Attention. When set to the default value of 0,
the drive reports a CHECK CONDITION for any UNIT ATTEN-
TION condition (power-on, SCSI bus reset, etc.)