Table 5-136 defect descriptor-block format, Table 5-135, Read defect data (10) command-field – Maxtor ATLAS 10K III User Manual

Page 176: Table 5-136, Defect descriptor-block format -112, Table 5-137, Table 5-135 r, Table 5-137)

Advertising
background image

SCSI Description

5-112

Maxtor Atlas 10K III

Table 5-135

READ DEFECT DATA (10) Command-Field DescriptionREAD DEFECT

1

All in-line spared blocks do not have an associated LBA, and, therefore, will not be

seen in Logical Block Format.

Table 5-136 shows the Block Format returned when the Defect List Format is 000b

Table 5-136

Defect Descriptor-Block Format.

Table 5-137 shows the Defective Bytes From Index Format when the Defect List
Format is 100b or the Physical Sector Format when the Defect List Format is 101b.

Table 5-137

Defect Descriptor-Bytes From Index Format, or Physical Sector Format

(KGNF

&GUETKRVKQP

PList

When the value is 0, the returned data does not include the Primary Defect List.

When the value is 1, the returned data includes the Primary Defect List. The defects
are returned in ascending order.

GList

When the value is 0, the returned data does not include the Grown Defect List.

When the value is 1, the returned data includes the Grown Defect List. The defects
are returned in order of occurrence.

When both PList and GList are set to 1, the Primary Defect List and the Grown Defect
List are returned. The Plist is returned followed by the Glist (the lists are not merged).
When both are set to 0, only the Defect List Header (Table 5-138) is reported to the
initiator.

Defect List

Format

This field specifies the format in which the defect descriptors are to be returned. The
supported formats are:

000b

Block Format (Table 5-136).

100b

Bytes from the Index (Figure 5-63). The data re-
turned from this mode does not include defects
outside normal user space.

101b

Physical Sector Format (Table 5-137). Default for-
mat. The defects returned from this mode do not
include defects outside normal user space.

110b

Vendor-Unique Format. This format is valid only
for the READ DEFECT DATA commands. The data
returned from this mode does not include defects
outside normal user space. Note that the vendor-
unique format is proprietary in nature and thus is
not documented in this Product Manual.

$KV

$[VG

















0 - 3

Defective Block Address

$KV

$[VG

















0 - 2

Cylinder Number of Defect

3

Head Number of Defect

4 - 7

Defective Bytes From Index / Defective Sector Number

Advertising