Maxtor ATLAS 10K III User Manual

Page 145

Advertising
background image

SCSI Description

Maxtor Atlas 10K III

5-81

RPL 00b

Rotational Position Locking is used for spindle synchronization in
storage arrays. The modes are:
00b – Disabled
10b – Master
01b – Slave
11b – Not supported
RPL can be overridden if the Maxtor (Vendor) Special Function
Control page Auto field value = 1.

6JKU FTKXG FQGU PQV UWRRQTV

URKPFNG U[PEJTQPK\CVKQP

Rotational Offset

0

Rotational Offset indicates the amount of rotational offset that
the drive uses when synchronized. The rotational offset is applied
in the retarded direction (lagging the synchronized spindle mas-
ter). The value in the field is determined by the following formula:
Offset

= 0 … 255

256

For example, a numerator of 128 indicates an offset of 1/2 revo-
lution (180°).

The valid parameter values are 0 to 255.

The specified value may be rounded. Rotational offset is not used
when the drive is configured as the synchronized-spindle master.

Medium Rotation

Rate

10021

The disk rotation speed in RPM.

(KGNF

8CNWG

&GUETKRVKQP